ENVIRONMENTAL SERVICES

Isokinetic Stack Monitoring
Req : Department of Environment (Environment Quality – Clean Air Regulation 1978)   

Local Exhaust Vertilation Monitoring
Reg : 17 & 18 Department of Occupational Safety and Health (DOSH)

Noise Monitoring - DOE and DOSH

Chemical Health Risk Assessment (CHRA) Regulation 9 of DOSH

Ambient Air Monitoring
Req : Malaysian Recommended Env. Air Quality Guideline

Water Analysis  (DOE Std A & B)
Refer to SAMM certificate No. 106


    


Traning

*All the chemical analysis is carried out by the SAMM’s accredited laboratory*


INDUSTRIAL HEALTH SERVICES
Evaluation, testing and monitoring of Local Exhaust Ventilation (LEV)
Control of Industrial Major Accident Hazards (CIMAH)
Chemical Health Risk Assessement (CHRA)
Environment Health and Safety Training (EHS) Consultancy Services, Training and Services

ADMINISTRATIVE SERVICES FOR
GOVERNMENTAL APPROVAL
Department of Occupational Safety and Health (DOSH)
Department of Environment (DOE)

*Registration and Submission*

ENGINEERING AND TRADING
Air Pollution Control Systems
Engineering Plastics Fabrication
Maintenance, Replacement & Overhaul (MRO)

COMPONENTS OF LEV

1.DEFINITION OF LEV SYSTEMLocal Exhaust Ventilation
2.WHAT IS LEV?

Force Ventilation

5 Major Components

An engineering control equipment for maintaining a clean, healthy and safe workplace

3.POOR LEV SYSTEMInefficient Design :
- Oversized duct and hood
- Undersized fan and dust collector

Wrong Practices :
- Hood is too far or too high
- Spray booth has too many spray painters

Poor Maintenance :
- Fan impellers with thick layer of paint

Misuse :
- To improve IAQ in productive floor
4.WHERE IS LEV MONITORING DONE?

Workplace :
- Production site
- Packaging site
- Chemical store / cabinet
- Spray Booth
- Fume Hood

5.WHEN IS LEV MONITORING DONE?

- Approximately 12 months after a new LEV system has been installed
- Process has contaminated air emission
- Heat stress
- Stack air or high humidity
- Odour

6.WHICH LEV SYSTEM NEEDS MONITORING?- The LEV system which is used as an engineering control equipment to reduce the exposure of workers to contaminated air
7.WHO CONDUCT THE LEV MONITORING?- Baseline and Periodic Monitoring
   An LEV competent person

- Monthly Monitoring
   Factory’s own technicians
8.LONG TERM BENEFITS OF LEV MONITORING- An improved LEV system performance
- An improved IAQ in production floor
- People are educated in LEV and IAQ matters
- Lower operation and maintenance cost
- Healthier working environment
- Less absentees
- Higher production